断路器安装作业指导书
精品文档---下载后可任意编辑 编码:BDDQ-ZW-03 批准: 审核: 编写: 精品文档---下载后可任意编辑 目次 1适用范围························································································································································ 27 2编写依据························································································································································ 27 3作业流程························································································································································ 27 4安全风险辨析与预控····································································································································28 5作业准备························································································································································ 28 6作业方法························································································································································ 29 7质量控制措施及检验标准····························································································································33 精品文档---下载后可任意编辑 1适用范围 本作业指导书适用于110~500kV电压等级,频率为50Hz的支柱式和罐式SF6断路器安装作业。 2编写依据 表2-1编写依据 序号 引用资料名称 1 GBJ147—1990《电气装置安装工程 高压电器施工及验收法律规范》 2 DL 408—1991《电业安全工作规程(发电厂和变电所电气部分)》 3 DL5009.3—1997《电力建设安全工作规程(变电所部分)》 4 Q/CSG10001—2024《变电站安健环设施标准》 5 Q/CSG10007—2024《电力设备预防性试验规程》 6 《10kV~500kV输变电及配电工程质量验收与评定标准第2部分:变电电气安装工程》 7 Q/CSG11105.2—2024《南方电网工程施工工艺控制法律规范》 8 《中国南方电网公司十项重点反事故措施》 3作业流程 作业(工序)流程见图3-1。 图3-1作业(工序)流程图 精品文档---下载后可任意编辑 4安全风险辨析与预控 4.1 断路器安装作业前,施工项目部根据该项目作业任务、施工条件,参照《电网建设施工安全基准风险 指南》(下简称《指南》)开展针对性安全风险评估工作,形成该任务的风险分析表。 按《指南》中与断路器安装作业相关联的《电网建设安全施工作业票》(编码:BDDQ-ZW-03-01/01), 结合现场实际情况进行差异化分析,确定风险等级,现场技术员填写安全施工作业票,安全员审核,施 工负责人签发。 4.3 施工负责人核对风险控制措施,并在日站班会上对全体作业人员进行安全交底,接受交底的作业人员 负责将安全措施落实到各作业任务和步骤中。 安全施工作业票由施工负责人现场持有,工作内容、地点不变时可连续使用10天,超过10天须重新 办理作业票,在工作完成后上交项目部保存备查。 表4-1作业任务安全基准风险指南 序号 危害名称 风险种类 风险等级 风险控制措施 1 无佩戴防护用品的作业人员 打击 可接受的风险 工作人员必须戴好安全帽、穿好工作服。站班 会时检查作业人员的防护用品 2 无资质的人员进行特种 作业 设备损坏 可接受的风险 由项目总工对特种作业人员资质进行审核,确保特种人员资质符合要求 3 关键工序不熟悉 设备损坏 可接受的风险 施工前由项目总工对施工人员进行详细的技术 交底 4 无防护的坑洞 跌落 可接受的风险 进行预埋螺丝安装前,安全员组织人员对安装 现场检查,先将周边的坑洞加盖封板 5 强度不足的基础 打击 可接受的风险 专人检查基础的强度,达到要求后,才进行支 架或底座安装 6 无证的司索人员 设备破损 可接受的风险 由项目总工对特种作业人员资质进行审核,确保特种人员资质符合要求 7 不合格的吊具 设备损坏 可接受的风险 使用前由专人检查,确保尼龙绳合格方可使用 8 未限位的人字梯 坠落 可接受的风险 断路器吊装时使用的人字梯应有紧固的铰链和限制开度的拉链 9 没系安全带(绳)的高 空作业人员 坠落 中等风险 对作业人员进行安全教育,技术交底,现场加强检查并设专人监护,高空作业人员作业前,必须系好安全带(绳) 10 未穿软底鞋进行高处 作业 坠落 中等风险 加强作业人员安全教育,进行技术交底,设专人监护,不穿软底鞋进行高空作业 11 移动时失去保护 坠落 中等风险 监护人员对高空作业人员进行监护,确保移动 过程中不能失去安全带保护 12 不当的瓷件吊装方式 设备损坏 可接受的风险 吊装瓷件时,采纳尼龙绳。当用钢丝绳吊瓷件 时,钢丝扣与瓷质接触部分,必须加缓冲物 13 滑脱的手工具 打击 可接受的风险 套筒及开口扳手用布带绑住系在施工人员手腕上,防止滑脱伤及人员 14 滑脱的手工具 设备破损 可接受的风险 套筒及开口扳手用布带绑住系在施工人员手腕上,防止滑脱伤及设备 精品文档---下载后可任意编辑 序号 危害名称 风险种类 风险等级 风险控制措施 15 不合格的气源 设备性能下降