蚂蚁文库
换一换
首页 蚂蚁文库 > 资源分类 > DOCX文档下载
 

无功功率补偿毕业论文中英文资料外文翻译文献

  • 资源ID:55779893       资源大小:952.27KB        全文页数:11页
  • 资源格式: DOCX        下载权限:游客/注册会员    下载费用:15积分 【人民币15元】
快捷注册下载 游客一键下载
会员登录下载
三方登录下载: 微信快捷登录 QQ登录  
下载资源需要15积分 【人民币15元】
邮箱/手机:
温馨提示:
支付成功后,系统会自动生成账号(用户名和密码都是您填写的邮箱或者手机号),方便下次登录下载和查询订单;
支付方式: 微信支付    支付宝   
验证码:   换一换

 
友情提示
2、PDF文件下载后,可能会被浏览器默认打开,此种情况可以点击浏览器菜单,保存网页到桌面,既可以正常下载了。
3、本站不支持迅雷下载,请使用电脑自带的IE浏览器,或者360浏览器、谷歌浏览器下载即可。
4、本站资源下载后的文档和图纸-无水印,预览文档经过压缩,下载后原文更清晰   

无功功率补偿毕业论文中英文资料外文翻译文献

精品文档---下载后可任意编辑 HARMONIC DISTORTION AND REACTIVE POWER COMPENSATION IN SINGLE PHASE POWER SYSTEMS USING ORTHOGONAL TRANSATION TECHNIQUE W. Hosny1and B. Dobrucky2 1 University of East London, England 2 University of Zilina, Slovak Republic ABSTRACT This paper reports a novel strategy for analysing a single phase power system feeding a non-linear load. This strategy is based on a new theory to trans the traditional single phase power system into an equivalent two-axis orthogonal system. This system is based on complementing the single phase system with a fictitious second phase so that both of the two phases generate an orthogonal power system. This would yield a power system which is analogous to the three phase power system but with the phase shift between successive phases equal to л/2 instead of 2л/3. Application of this novel approach makes it possible to use the complex or Gauss domain analytical in a similar way to the well known of instantaneous reactive power for three phase power system instigated by Akagi et al in 1983. Thus, for the fictitious two-axis phase power system, the concept of instantaneous active and reactive power could be instigated. Moreover, the concept of instantaneous power factor could be defined. The novel strategy of power system analysis outlined in this paper is applied to a single phase power system feeding a non-linear load in conjunction with an active power filter. The latter serves the purpose of compensating for either of the instantaneous reactive power or the harmonic current distortion in the single phase power system under investigation or for compensating of both. Experimental results demonstrated the effectiveness of the novel single phase power system analysis reported in this paper. Keywords single phase power systems, orthogonal transation technique, harmonic distortion and reactive power compensation 1 INTRODUCTION In this section the orthogonal transation technique applied to a single phase power system instigated by Akagi et al, reference [1], is described. By adopting this technique expressions for the reference currents used in an active power filter for the compensation of harmonic distortion or reactive power or both, are derived. Consider a single phase power system which is defined by its voltage and current as follows vRet V Cos ωt 1 iRet I Cos ωt – Ф Where V and I respectively are the peak values of the voltage and current, ω is the angular frequency of the power supply and Ф is the phase shift between voltage and current. The power system described by Eq.1 is termed as the real part in a complex power system and is complemented by a fictitious/imaginary phase defined as follows Vimt V Sin ωt

注意事项

本文(无功功率补偿毕业论文中英文资料外文翻译文献)为本站会员(shugezhang1)主动上传,蚂蚁文库仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。 若此文所含内容侵犯了您的版权或隐私,请立即通知蚂蚁文库(发送邮件至2303240369@qq.com或直接QQ联系客服),我们立即给予删除!

温馨提示:如果因为网速或其他原因下载失败请重新下载,重复下载不扣分。




关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们


网站客服QQ:2303240369

copyright@ 2017-2027 mayiwenku.com 

网站版权所有  智慧蚂蚁网络

经营许可证号:ICP备2024020385号



收起
展开